    Combines the temperature measurement functions that are ideal for industrial, electrical, and HVAC/R professionals. This infrared and contact thermometer measures both IR and contact temperature. Additionally, it features a handy Velcro® pipe probe or, plug in any industry standard, K-type mini-connector thermocouple probe.
    Brand:
    Fluke
    Model:
    561
    Order No:
    561
    Condition:
    NEW
    Description
    Fluke 561 HVAC/R Infrared and Contact Thermometer
    Features
    IR thermometer for quick measurements up close, or at a distance, without a ladder
    Contact thermometry capability, compatible with all standard mini-connector K-type thermocouples, preserves your investment in thermocouples
    Velcro® pipe probe for superheat and sub-cooling and other contact and ambient measurements
    Single-point laser sighting
    Easy emissivity adjustment for measuring pipes and other shiny materials more accurately
    Lightweight and portable
    Very easy to use
    Efficient—no need to shut down equipment when making IR measurements
    MIN, MAX, and DIF functions help you quickly identify problems
    Scan large areas or small objects quickly and efficiently
    An IR and contact thermometer that means the needs of most industrial and residential temperature applications
    Combines the temperature measurement functions needed by industrial, electrical, and HVAC/R professionals in one tool. It features K-type thermocouple capability enabling users to take contact temperature measurements. This tool is fast, efficient, and easy to use.
    Use its IR capabilities to scan large areas or small objects quickly and efficiently, without shutting down any equipment. You can also measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor and leave your ladder in the truck.
    Use the handy flexible pipe probe (included) to take super-heat or internal temperatures. Or plug in any industry standard type K mini connector thermocouple probe to take those measurements and preserve your investment in thermocouples you already own.
    Laser-guided sighting for IR measurements
    When using this tool in the IR mode, the single dot, laser sighting system guides measurements to the right target. The dot indicates the approximate center of the measurement area.
    Applications
    Electrical
    HVAC/R
    Industrial
    Facilities maintenance
    Included
    Thermometer
    K-Type Thermocouple Velcro® Pipe Probe
    Carrying Case
    AA Batteries
    Users Manual
    Specifications
    Temperature
    -40 to 1022°F (-40 to 550°C)
    Display Resolution
    0.1°F (0.1°C) of reading
    D:S (Distance to Spot Size)
    12:1
    Easy Emissivity Selector
    Adjustable with three settings:
    Low (0.3)
    Medium (0.7)
    High (0.95)
    Display Accuracy (Assumes Ambient Operating Temperature of 73 to 77°F (23 to 25°C))
    ±1.0% of reading ±1% of reading or ±2°F (±1°C), whichever is greater below 32°F (0°C), ±2°F (±1°C) ±0.1°/1°
    Response Time
    500 mSec (95% of reading)
    Repeatability
    ±0.5% of reading or ±2°F (±1°C), whichever is greater
    Spectral Response
    8 to 14 µm
    Laser Sighting
    Single point laser
    Laser Shutoff
    Laser turns off above ambient temperature of 104°F (40°C)
    Laser Power
    Class 2(II) operation; Output <1 mW, wavelength 630 to 670 nm
    Relative Humidity
    10 to 90% RH non-condensing, at <86°F (30°C)
    Power, Battery Life
    2 x AA batteries (alkaline or NiCD)
    Battery Life
    12 hours
    Display Hold
    7 seconds
    Backlit Display
    Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options
    Operating Temperature
    32 to 120°F (0 to 50°C)
    Storage Temperature
    -25 to 150°F (-20 to 65°C)
    MAX, MIN, DIF Temperatures
    Yes
    Thermocouple Type K Mini Adapter Input
    Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range.
    Thermocouple Type K Fabric Hook-and-Loop Fastener Pipe Probe
    Yes, with a temperature range of 32 to 212°F (0 to 100°C) and accuracy of ±4°F (±2.2°C)
    HVAC Measurement Guide
    Yes
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.