-40%

14/18L Dental Autoclave Steam Sterilizer Medical Sterilization Stainless Steel

$ 528

Availability: 11 in stock
  • Brand: Unbranded
  • Restocking Fee: No
  • Sterilize pressure: 0.12Mpa
  • Sterilize time: 25Min
  • G.W: 15KGS
  • Material: Stainless steel #304
  • Sterilizer temperature: 121℃
  • Return shipping will be paid by: Buyer
  • Power: 900W
  • Condition: New
  • Refund will be given as: Money Back
  • Chamber capacity: Ø25×D28CM (Ø9.84×D11.02inch)
  • All returns accepted: Returns Accepted
  • MPN: 1020100931C
  • Inside capacity: 14 Liter
  • Item must be returned within: 30 Days
  • Intended Use/Discipline: Dental Laboratory

    Description

    Ship from USA to USA
    14L Dental Steam Autoclave Sterilizer Medical Sterilization S/S 304 Lab
    Description:
    Chamber capacity:Ø25×D28CM (Ø9.84×D11.02inch)
    Inside capacity:14 Liter
    Material:Stainless steel #304
    Outside Size :46.5*35*36 CM
    Packing Size :51*39*40 CM
    G.W:15KGS
    Sterilizer temperature:121℃
    Sterilize pressure:0.12Mpa
    Sterilize time:25Min
    Power:900W
    AC110V/8A
    AC220V/4A
    Auto supply water system: Manual give the water
    Safety valve: automatic discharge in excess of standard value
    Temp and Press display:Pressure gauge
    Disinfection principle:Uses the vapor power emissions cold air / 2 times
    Operation Steps:
    1.Plug in the power cord
    2.Shut exhaust needle valve in the Close (clockwise)°
    3.Adding about 800 ml of distilled water. Close the door cover, tight the rotate handle
    4. Start the timer knob to 121 ℃ position. Sterilization is working.
    5.Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction)
    6.Wait for the pressure gauge pointer to zero, opened the door cover
    Caution:
    Every time sterilization, must add about 800 ml of distilled water
    Use a separate socket (confirm the socket of the output voltage)
    Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valve
    Packing:
    main unit 1pc
    Standard accessories:
    Plate 3pcs ( Size:21*15.5*2 cm)
    Shelf 1pc
    Take Plate tool 1pc    steam exhaust pipe  1pc(1 meter length)
    ++++++++++++++++++++++++++++++++++++++
    18L Dental Autoclave Steam Sterilizer Medical Sterilization with Drying Function
    Description:
    Voltage:110V; 50Hz/60Hz
    Heater Power: 1100W
    Tank capacity: 18L
    Inside dimensions: Φ250 x D350mm
    Sterilize temperature: 122℃ & 134℃
    Sterilize pressure: 0.12Mpa & 0.23Mpa
    Sterilize time: 25min & 6min
    Drying time: 40min
    Tank Material: Stainless steel #304
    Machine size (L*W*H): 60 * 39 * 36cm
    Packing size (L*W*H): 61 * 53 * 40cm
    N.W.: 33KG
    G.W.: 35KG
    Standard accessories: (Plate * 3PCS; Shelf * 1PC; Plate Taking tool * 1PC)
    Application: For dental, surgery, beauty salon, medical care, laboratory, and so on.
    Caution:
    1.After the completion of disinfection,please to wait for 10 minutes.
    Pressure Gauge in red area. Do not rotate handle, open the steam discharge valve firstly.
    2.Before each use,must supply water 800ml of distilled water .
    3.Please close steam discharge valve before the disinfection.
    4.Do not use any corrosive or chemical water as the disinfection.
    5.Do not share the same electricoutllet with other electrical apparetus.
    6.Please pay attention to correct voltage and frequency.
    7.Connect steam exhaust pipe with the steam vent,before operation.
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory  agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your  status as an authorized purchaser of this item before shipping of the item.
    Seller name:DEERBELL
    City,State:SHENZHEN,China
    Telephone number:0755-36925817
    K181993
    Device Classification Name    Sterilizer, Steam
    510(K) Number    K181993
    Device Name    STURDY Autoclave Super Microm (Models SA-260MA And SA-260MA-R)
    Regulation Number    880.6880
    Classification Product Code    FLE
    Date Received    7/26/2018
    Decision Date    11/1/2019
    Device Class    2
    Regulation Number    21CFR880.6880